Roll to Roll supported model MR262-GFR
Roll to Roll supported model
MR262-GFR
MR262-GFR
A 260 mm wide roll transfer type machine. Continuity/insulation test with ±5 μm high accuracy is possible. With the grip feeding system, which is unlikely to damage work sheets, work sheets are fed.
Applications
Application examples |
|
---|
Max. work sheet size | Roll width : 260mm |
---|---|
Max. test fixture size | When rotating:φ200mm When not rotating:X275 x Y100mm |
Work sheet transfer | Loading:Roll Unloading:Roll |
Dimensions
Specifications
Model | MR262-GFR | |
---|---|---|
Type | MR262-GFR-M5S | |
Application examples | Flex PCB, Rigid Flex PCB | |
Test capability | Max. number of test points | Upper head:1,534 / Lower head:1,022 |
Work sheet size | Roll witdh : 100~260mm | |
Max. test range*1 | X400 x Y260 mm | |
Max. test fixture size | When rotating:φ200mm / When not rotating:X275 x Y100mm | |
Positioning accuracy*2 | ±5μm | |
Test specifications | Determination method | Open/short (pass/fail determined based on specified resistance value) |
Open test*2 | Test range: 2 wire test 10Ω~ 10kΩ (0.5mA,10mA) 4 wire test 1mΩ~ 500Ω (10mA, 40mA, 100mA) |
|
Open voltage: 15V ~ 50V | ||
Test accuracy: 2 wire test ±10% (50Ω~ 10kΩ), ±5Ω (10Ω~ 50Ω) 4 wire test ±10% (1mΩ ~ 500Ω) |
||
Short test*2 | Test range: 100kΩ~ 100MΩ | |
Test voltage: 50V ~ 250V | ||
Test accuracy: ±10% | ||
Options | μ Short test, Spark detection, Heating test, Non contact test | |
Work sheet transfer | Loading / Unloading | Rolll |
Image processing | Camera view | X2.4 x Y1.8mm (standard) |
Pattern detection | Pattern recognition via grayscale | |
Illumination type | Transmission light, reflection light | |
Hardware | Interface | LAN・USB |
Display | 15 inch LCD with touch panel | |
Software | OS | Windows7 |
Production support function | Automatic fixture correction, output of test result log, automatic retry test, fixture stroke count | |
Usage environment | Weight | Approx. 1,300kg |
Power supply | 1-phase, 180 to 240V AC, 50/60Hz, 6kVA | |
Dry air | 0.5MPa |
- The actual test range varies depending on the fixture shape, holding range, etc.
- Data taken from our performance test.
Contact point
Inquiry by email
- Request an estimate
- Request a demonstration
- Request a catalog
- Request detailed specifications
Inquiry by phone
+81-53-467-3601